Journeyman Electrician Practice Test 1: Code Fundamentals & Wiring Methods

General requirements from Articles 100 and 110, Chapter 3 wiring methods, conductor insulation markings, and Article 314 box fill with five worked volume calculations.

Pick an answer to lock it in and see the explanation with the NEC section for the 2023 and 2026 editions. The clock starts with your first answer. Aim for 14 of 20, the 70% line Texas and many other states use.

0/20 answered0 correct0:00
  1. Question 1 of 20General Requirements

    While inspecting a piece of commercial electrical equipment, you notice a manufacturer label displaying the equipment's SCCR. What does this acronym stand for?

  2. Question 2 of 20General Requirements

    Equipment intended to interrupt current at fault levels—such as a circuit breaker or fuse—must have an interrupting rating at least equal to what value?

  3. Question 3 of 20Working Space

    What is the minimum working clearance required in front of a 480V switchboard where there are exposed live parts on one side and a concrete/block wall (grounded) on the other side?

  4. Question 4 of 20Terminations

    Unless the equipment is listed and marked otherwise, conductor ampacity for circuits rated over 100 amperes shall be selected from which temperature column of the NEC ampacity table?

  5. Question 5 of 20Services

    The service point is defined as the point of connection between:

  6. Question 6 of 20Underground Wiring

    For a general location (not under a building, slab, driveway, or any other special condition in the burial-depth table), what is the minimum cover required for direct-buried cable versus a listed nonmetallic raceway (PVC)?

  7. Question 7 of 20Underground Wiring

    You are installing underground residential service conductors in a trench that is 24 inches deep, and the conductors are not encased in concrete. To warn future excavators, the NEC requires a warning ribbon to be placed in the trench. What is the minimum required distance this warning ribbon must be placed above the underground installation?

  8. Question 8 of 20Raceways

    You are installing a run of Electrical Metallic Tubing (EMT) for a new branch circuit. According to the NEC, at what point in the installation are you permitted to pull the insulated conductors into the raceway?

  9. Question 9 of 20EMT

    Electrical Metallic Tubing (EMT) is a highly versatile wiring method. Based on the 'Uses Permitted' rules for EMT, in which of the following specific locations is EMT explicitly allowed to be installed?

  10. Question 10 of 20Raceway Fittings

    When running EMT, what is the minimum conductor size that requires an insulated fitting (such as a plastic bushing) to protect the wire from abrasion?

  11. Question 11 of 20Conductors in Raceways

    Under what condition are 120V and 277V circuit conductors permitted to occupy the same conduit or raceway?

  12. Question 12 of 20Conductor Insulation

    You are installing feeder conductors in an underground PVC conduit, which is classified as a wet location. To maximize your allowable ampacity and use the 90°C column for derating, which of the following conductor insulation markings must you use?

  13. Question 13 of 20Conductor Insulation

    When looking at the insulation type of a conductor, what does the letter 'W' indicate about its approved application?

  14. Question 14 of 20Box Fill

    A 12 AWG solid conductor enters a junction box and loops through without being spliced or terminated to any device. The total length of this unbroken loop inside the box measures 14 inches. When calculating the total box fill, how many conductor volume allowances must be counted for this specific wire?

  15. Question 15 of 20Conduit Bodies

    An electrician installs a 3/4-inch Type C conduit body in the middle of a long straight run of EMT. Under what condition is the electrician permitted to make wire splices inside this conduit body?

  16. Question 16 of 20Box FillCalculation

    Three conduits enter a junction box containing the following: six 12 AWG conductors, three 12 AWG equipment grounding conductors, three splices, three 12 AWG pigtails, three lock rings, and one duplex receptacle. What is the total conductor volume allowance count (equivalent number of wires) for this box?

  17. Question 17 of 20Box FillCalculation

    A junction box contains four 10 AWG conductors, six 12 AWG conductors, and five 12 AWG equipment grounding conductors. What is the total minimum volume required for this box in cubic inches?

  18. Question 18 of 20Box FillCalculation

    A 4-inch square box that is 2-1/8 inches deep is installed with an extension ring. The extension ring is stamped with a marked volume of 21.0 cubic inches. According to the NEC, what is the total available volume of this assembled enclosure?

  19. Question 19 of 20Box FillCalculation

    A junction box contains six 12 AWG equipment grounding conductors (EGCs). How many total conductor volume allowances must be counted for these ground wires?

  20. Question 20 of 20Box FillCalculation

    A box contains 6 current-carrying 12 AWG conductors, 3 equipment grounds, one internal clamp, and one device yoke. Using 2.25 cu in per 12 AWG conductor, what is the minimum required box volume?