Free practice test 2 of 3 · 20 questions · 3 calculations

Journeyman Electrician Practice Test 2: Services, Grounding & Branch Circuits

Article 230 service clearances and disconnects, Article 250 grounding and bonding (GEC and EGC sizing, electrodes, bonding at the service), branch-circuit and device rules, and Article 220 dwelling demand factors with three worked calculations.

Pick an answer to lock it in and see the explanation with the NEC section for the 2023 and 2026 editions. The clock starts with your first answer. Aim for 14 of 20, the 70% line Texas and many other states use.

0/20 answered0 correct0:00
  1. Question 1 of 20Service Clearances

    What is the minimum overhead clearance required for service-drop conductors passing over a residential property and driveway?

  2. Question 2 of 20Service Disconnect

    Where must the service disconnecting means be installed relative to the service entrance conductors entering the building?

  3. Question 3 of 20Service Raceways

    What is the general rule regarding the installation of feeder or branch-circuit conductors within the same raceway as service conductors?

  4. Question 4 of 20Dwelling Services

    For a single-family dwelling, when calculating the minimum ampacity for ungrounded service-entrance conductors that supply the entire load of the dwelling, the NEC permits these conductors to have an ampacity of not less than what percentage of the service rating?

  5. Question 5 of 20Grounding Electrode Conductor

    What is the minimum size Copper Grounding Electrode Conductor (GEC) required for a standard residential 200-Ampere service supplied by 2/0 AWG Copper service-entrance conductors?

  6. Question 6 of 20Bonding Jumpers

    Which of the following conductors is NOT sized based on the size of the ungrounded (phase) conductors?

  7. Question 7 of 20Equipment Grounding

    What is the minimum size copper equipment grounding conductor for a circuit protected by a 60-ampere overcurrent device?

  8. Question 8 of 20Grounding Electrodes

    When a single ground rod has a resistance greater than 25 ohms, what is required?

  9. Question 9 of 20Grounding Electrodes

    To qualify as a grounding electrode, a metal underground water pipe must be in direct contact with the earth for a minimum distance of:

  10. Question 10 of 20Equipment Grounding

    A contractor uses a 5-foot whip of Flexible Metal Conduit (FMC) as the sole equipment grounding conductor (EGC) for a 100-amp transformer feeder. Is this compliant?

  11. Question 11 of 20Service Bonding

    When ensuring electrical continuity at service equipment, which of the following is strictly prohibited from being used as the sole means of bonding?

  12. Question 12 of 20Grounding Electrodes

    Unless otherwise listed for multiple conductors, how many grounding electrode conductors are permitted to be connected to the grounding electrode by a single clamp or fitting?

  13. Question 13 of 20Receptacle Spacing

    What does the NEC require for the spacing of general wall receptacles in a residential living room?

  14. Question 14 of 20Wet-Location Receptacles

    A 20-amp, 125-volt nonlocking receptacle installed in a wet location must be listed as what type?

  15. Question 15 of 20Luminaires

    When installing luminaires, what is the vertical height of the restricted zone, measured from the top of the bathtub rim, within which hanging fixtures are prohibited?

  16. Question 16 of 20Panelboards

    When determining the maximum number of overcurrent devices permitted in a panelboard, a 3-pole circuit breaker shall be considered as what?

  17. Question 17 of 20Range DemandCalculation

    What is the feeder demand load for a single 14 kW household electric range rated at 240 volts?

  18. Question 18 of 20Cooking Appliance DemandCalculation

    What is the minimum calculated demand load for four household wall-mounted ovens, each having a nameplate rating of 5 kW?

  19. Question 19 of 20Dryer DemandCalculation

    For multifamily dwellings, what is the demand factor for 16 household electric clothes dryers?

  20. Question 20 of 20Appliance Demand

    What demand factor can be applied to four or more fastened-in-place appliances in a dwelling unit?